LEEDERVILLE - PERTH WA

Specialist Disability Accommodation (SDA) - Suitable for single occupancy High Physical Support, Fully Accessible and Improved Liveability.

bed icon

2 Accessible Bedrooms

shower icon

1 Accessible Bathrooms

car-garage icon

1 Parking Bay

calendar icon

Available Now

Download our tenant brochure

Including floor plans, apartment availability and property inclusions

3D VIRTUAL TOUR

Click the 'View 3D Tour' button below to get a full 360 walk through of one of the completed display apartments. Furnishing supplied is optional and can be configured for each resident's needs.

Location

  • 200m to the heart of leederville

  • 400m to Leederville train station

  • 10 minute drive to Innaloo Shopping Centre

  • 10 minute drive to the Perth CBD

Property Benefits

This property includes Innogreen Rental Benefits available to all SDA tenants.

Assistive Technology

Smart home assistive technology provided by Innogreen Technologies.

Shared onsite supports

All our single occupancy apartments include a concierge service available 24/7 for any ad hoc supports you may need. Download our Shared onsite supports brochure to learn more

Floorplan - single resident apartment

PROPERTY SPECIFICATION

Entrance, Doorways and Door Hardware
  • A level landing of 1500mm x 1500mm with a maximum gradient and crossfall provided at the level (step-free) external doorway.

  • The level landing area shall be increased to accommodate door circulation spaces.

  • All external doorways must have a minimum clear opening width of 950mm.

  • Door handles installed at 1000mm above finished floor level.

Corridors, Flooring and Windows
  • All internal corridors and passageways provide a minimum clear width of 1200mm.

  • Internal floor finishes have a minimum slip resistance rating of R10.

  • Windows with handles installed no higher than 1000mm above finished floor level.

Bedroom and Living Room
  • The dwelling's bedroom size allow for a Queen bed size of 1530mm x 2100mm. There is 1540mm on any one side of the bed, the other two sides (foot of bed included, bedhead excluded) have a minimum of 1000mm.

  • The family/living room has a minimum free space of 2250mm in diameter, clear of furniture.

Switches and GPOs
  • Light switches at 1000mm above the finished floor level and horizontally aligned with the door handle at the entrance to the room.

  • Dimmable lighting switches in living areas and bedrooms.

  • GPOs and light switches are rocker action in design with a minimum width of 35mm.

  • GPOs are installed at 1000mm above finished floor level.

Minimum General Requirements
  • One bedroom

  • One bathroom

  • One living area

  • One kitchen

  • One laundry

  • Ducted AC with zone control in living room and participant bedroom

  • Ceiling hoist provision in bedroom

Accessibility from Boundary & Car Park
  • A safe, continous step-free accessway from the front boundary of the site to an entry doorway of the dwelling.

  • A safe, continous step-free accessway from car parking associated with the dwelling (excluding staff only parking), to an entry doorway of the dwelling.

Heating and Cooling
  • Ducted air-conditioning shall be provided to living areas and bedrooms with control panels in an accessible location at 1000mm from FFL and not closer than 500mm to any internal corner.

Ceiling Hoists
  • Where required by the participant, bedrooms shall have a provision for power and inbuilt structure, capable of installation of a constant charge ceiling hoist.

  • The hoist shall be capable of going across the bed and down the bed. Min load capacity of the hoist shall be 250kg.

Storage
  • A dwelling must be provided with a storage cupboard with a minimm 600mm width and adjustable shelf heights.

  • The storage cupboard is required to be separate to the participant's bedroom robe.

Assistive Technology
  • Internet connection with the ability for high internet speeds to be maintained and stable in nature with wi-fi coverage throughout all areas of the dwelling.

  • Intercom system to enable communication between the participant and their supports when not within line of sight.

Emergency Power Solutions
  • Emergency power solutions to cater for a minimum 2-hour outage in no less than 2 double GPOs in participant bedrooms and any provided automated doors that are used for entry or exit.

READY TO GET STARTED?