Property Benefits

This property includes Innogreen’s Rental Benefits available to all SDA tenants.

Assistive Technology

Smart home assistive technology provided by Innogreen Technologies.

Exterior

Modern house exterior with a concrete driveway, gray fence, and white stucco walls under a clear blue sky.

Living Area

Empty living room with beige tiled floor, white walls, ceiling lights, air conditioner, small windows, chairs, a wooden bench, a white refrigerator, and a glass door leading outside.
Empty living room with two wooden chairs, kitchen area with white cabinets and stainless steel appliances, doorways leading to other rooms, and light-colored tiled flooring.

Kichen

Small kitchen corner with a gas stove, oven, microwave, toaster, and sink with exposed plumbing.
Empty kitchen with white cabinets, beige tiled floor, and a doorway leading to a room with a hospital bed.

Accessible Bedroom 1

Empty room with light-colored hardwood floors, white walls, a window with blinds, and a white closet door. There are recessed ceiling lights and a small bathroom area visible in the background.
Empty room with beige walls, hardwood floor, ceiling light, air conditioner, and electrical outlets.

Accessible Bedroom 2

Empty bedroom with a wooden bed frame, plastic-wrapped mattress, small side table with a yellow lamp, air conditioning unit on wall, window, and sliding door leading to another room.
Empty hospital room with a bed, window, air conditioner, and small table.

Accessible Bathroom

Bathroom corner with a wall-mounted sink, mirror, and a small stool with towels, and a grab bar on the adjacent wall.

Support Worker Room

Minimalist bedroom with a bed, a small wooden nightstand, a lamp, and a window with blinds, neutral wall color, and wooden flooring.

Rear Courtyard

Outdoor patio with a white table with black surfaces and two black chairs, plain light-colored exterior wall, open door leading to an indoor room.

Floor Plan

PROPERTY SPECIFICATION

Open door with a handle
Entrance, Doorways and Door Hardware
  • A level landing of 1500mm x 1500mm with a maximum gradient and crossfall shall be provided at the level (step-free) external doorway.

  • The level landing area shall be increased to accommodate door circulation spaces. A doorway threshold ramp (if required) is permitted to be within the landing area.

  • All external doorways must have a minimum clear opening width of 950mm.

  • Door handles must be installed between 900mm and 1100mm above finished floor level.

Four blue squares arranged in a diamond shape.
Corridors, Flooring and Windows
  • All internal corridors and passageways must provide a minimum clear width of 1200mm when measured from skirting to skirting.

  • All internal floor finishes must have a minimum slip resistance of P3 or R10

  • The dwelling must have window in living areas and one window in each participants bedroom. Windows must not be installed higher than 1000mm above finished floor level.

Simple line drawing of a bed
Bedroom and Living Room
  • The dwelling's bedroom size must allow for a Queen bed size of 1530mm x 2100mm. There must be 1540mm on any one side of the bed, the other two sides (foot of bed included, bedhead excluded) must be a minimum of 1000mm.

  • The family/living room must accommodate a minimum free space of 2250mm in diameter, clear of furniture.

Lightbulb icon with a hand inside
Switches and GPOs
  • Light switches must be positioned in a consistent location between 900mm and 1000mm above the finished floor level and horizontally aligned with the door handle at the entrance to the room.

  • Dimmable lighting switches shall be proivided in living areas and bedrooms.

  • GPOs and light switches must be a rocker action, toggle or push pad in design with a minimum width of 35mm.

  • GPOs must be installed between 600mm and 1100mm above finished floor level.

Icon of a house with a pitched roof.
General Inclusions
  • One bedroom

  • One bathroom

  • One living area

  • One kitchen

  • One laundry

  • One split system AC in living room and participant bedroom

  • Ceiling hoist in bedroom

Icon of a bent arrow pointing upward and then curving downward
Accessibility from Boundary & Car Park
  • A safe, continous step-free accessway shall be provided from the front boundary of the site to an entry doorway of the dwelling. The accessway may include a walk way, step ramp or ramp along.

  • A safe, continous step-free accessway shall be providing from the any car parking associated with the dwelling (excluding staff only parking), to an entry doorway of the dwelling.

Air conditioner with cool air and snowflake symbol
Heating and Cooling
  • Reverse cycle air-conditioning shall be provided to living areas and bedrooms with control panels in an accessible location between 900mm and 1100mm from FFL and not closer than 500mm to any internal corner.

Icon of a person in a wheelchair.
Ceiling Hoists
  • Where required by the participant, bedrooms shall have a provision for power and inbuilt structure, capable of installation of a constant charge ceiling hoist.

  • The hoist shall be capable of going across the bed and down the bed. Min load capacity of the hoist shall be 250kg.

Blue filing cabinet with four drawers
Storage
  • A dwelling must be provided with a storage cupboard with a minimm 600mm width and adjustable shelf heights.

  • The storage cupboard is required to be separate to the participant's bedroom robe.

Icon of a computer monitor with a globe and signal lines, representing internet or online connection.
Assistive Technology
  • Internet connection shall be provided with the ability for high internet speeds to be maintened and stable in nature with wi-fi coverage throughout all areas of the dwelling.

  • A video, intercom or other communication system shall be provided to enable communicatin between the participant and their supports when not within line of sight.

Blue alarm siren icon with sound waves
Emergency Power Solutions
  • Emergency power solutions shall be provided to cater for a minimum 2-hour outage in no less than 2 double GPOs in participant bedrooms and any provided automated doors that are used for entry or exit.